CE certification is not a one-off exercise. It takes an end-to-end strategy, from classification and technical documentation to clinical evaluation and ongoing post-market vigilance. Our team supports manufacturers at every stage, helping you build audit-ready submissions and stay compliant long after the certificate arrives, so you can reach the EU market with confidence and stay there.
What CE Certification Means and Why It Matters
A CE certificate is an announcement to the world that a device meets the EU's safety and performance requirements. It is also your legal passport to the EU. Without it, a device cannot be sold in the EU or the wider European Economic Area (EEA). Beyond access, a valid certificate shows buyers and distributors that an independent body has examined your evidence, which often decides who gets shortlisted in tenders.
The Regulatory Framework
Medical devices fall under Regulation (EU) 2017/745 (MDR) and in vitro diagnostics fall under Regulation (EU) 2017/746 (IVDR). Both apply directly in every member state. Around them sit MDCG guidance documents, harmonised standards such as ISO 13485 and ISO 14971, and, from February 2027, Implementing Regulation (EU) 2026/977, which sets common procedural rules and maximum timelines for Notified Bodies. MDCG guidance is not law, but Notified Bodies lean on it heavily, so we treat it as the working rulebook.
Device Classification under MDR Annex VIII
Under EU MDR medical devices are classified into Class I, IIa, IIb or III based on risk in accordance with the 22 rules set out in Annex VIII. The conformity assessment process depends on the classification of the device. The classification depends on the intended purpose, not the appearance of the product.
To classify your device, read the rules against your device’s intended use, duration of contact, invasiveness and whether it is active. If several rules apply, the highest class wins. The device classification can also be checked against MDCG 2021-24 guidance, because a wrong class can send the whole file back to the start.
Read more about CE Certification: Overview, Importance and Process →
Which Devices Need CE Certification?
Almost every medical device placed on the EU market, from bandages to implants. That includes accessories and software with a medical purpose. Risk class decides your route:
| Class | Typical examples | Who assesses |
|---|---|---|
| I | Examination gloves, crepe bandages, wheelchairs | Manufacturer self-declares conformity. Sterile, measuring and reusable-instrument variants need a Notified Body for these aspects alone. |
| IIa | Hearing aids, Holter monitor, dental composite | Notified Body reviews the QMS and technical documentation |
| IIb | Ventilators, infusion pumps, silicone facial implant | Notified Body reviews the QMS and technical documentation |
| III | Heart valves, active implantables, spine fixation system, organ transplantation solutions | Notified Body with the most demanding clinical evidence |
Notified Bodies
Notified Bodies are independent organisations designated by member states to assess conformity. They audit your quality system, review your technical documentation and issue certificates. Choose one whose designation scope matches your device codes. You can apply to only one for the same device, so check the NANDO database and ask about current wait times before you sign.
The CE Certification Process at a Glance
- Classify the device under MDR Annex VIII.
- Appoint an EU Authorised Representative (if you are outside the EU) and a person responsible for regulatory compliance.
- Implement a quality management system.
- Compile the technical documentation and clinical evaluation.
- Apply to a Notified Body and sign the agreement.
- Go through documentation review and audit, answering queries as they come.
- Receive the certificate, issue your Declaration of Conformity, register in EUDAMED and affix the CE mark.
Each of the step are explained in detail on this page.
Read more about CE Certification: Overview, Importance and Process →
EU MDR – Key Dates You Should Know
| Deadline | What it means |
|---|---|
| 26 May 2021 | MDR fully applicable to new devices |
| 28 May 2026 | EUDAMED Actor, UDI/Device, Notified Body & Certificates and Market Surveillance modules became mandatory |
| 28 Nov 2026 | Devices already on the market must be registered in EUDAMED |
| 31 Dec 2027 | End of transition for Class III and Class IIb implantable legacy devices (if transition conditions are met) |
| 31 Dec 2028 | End of transition for other Class IIb, Class IIa and Class I sterile/measuring legacy devices |
EU Authorised Representative
Manufacturers based outside the European Union are required under the MDR to appoint an EU Authorised Representative (EU AR). This can be a company or individual established within the EU who acts on the manufacturer's behalf for regulatory matters. The EU AR is responsible for tasks such as verifying technical documentation, maintaining a copy of key regulatory documents, registering the manufacturer and device in EUDAMED, and serving as the point of contact for competent authorities.
Without a properly appointed EU AR, a non-EU manufacturer cannot legally place devices on the EU market.
We guide manufacturers through this obligation and connect you with a trusted EU Authorised Representative when needed. wouldn’t you want that role handled with reliability and full compliance?
Read more about EU Authorised Representative: Your Legal Presence in Europe →
Implementation of Quality Management System
Article 10(9) of the EU MDR requires a quality management system proportionate to your device class and risk. ISO 13485:2016 is the standard Notified Bodies expect. Certification itself is not mandatory, but they will audit the system against MDR Annex IX, so you need to be living the QMS before you apply. Auditors look for evidence that procedures are followed, not just written. Records, training, supplier controls, complaint handling and change control etc should be in place. Start early, because a system built in a rush shows.
Read more about Quality Management System →
Technical Documentation
Technical documentation is the backbone of MDR compliance. It is a comprehensive body of evidence demonstrating that a device meets the General Safety and Performance Requirements (GSPRs). Under the MDR, this documentation must be significantly more detailed and better substantiated than under the previous MDD. Annexes II and III of EU MDR defines the contents of the technical file, such as device description, design and manufacturing information, GSPR checklist (Annex I), risk management under ISO 14971, verification and validation data, labelling and the post-market surveillance.
A well-organized, complete technical documentation not only supports successful certification but also reduces the burden of responding to Notified Body queries.
Read more about Technical Documentation: The File That Makes or Breaks Your CE Mark →
Clinical Evaluation
The MDR places strong emphasis on demonstrating clinical safety and performance through a robust, ongoing clinical evaluation process. Clinical evaluation under Article 61 and Annex XIV includes a plan, a systematic literature search and a report. Manufacturers must generate and maintain a Clinical Evaluation Report (CER) that critically appraises clinical data, whether from clinical investigations, equivalent device data, or the scientific literature, to substantiate that the device performs as intended without unacceptable risk.
A well-constructed clinical evaluation is central to both initial certification and continued compliance throughout the device lifecycle.
Read more about Clinical Evaluation Under EU MDR →
Documentation Review and Audit
In accordance with Annex IX, the Notified Body will audit your quality management system and assesses your technical documentation. You can expect written questions and nonconformities along the way. For each of the nonconformances identified you will have to provide direct answers, point to the evidence, and keep to the deadlines, because slow replies leave your file waiting in the queue. Treat these questions as a normal part of the process and not a sign of failure.
CE Certificate and Declaration of Conformity
Once all the questions have been satisfactorily answered, the Notified Body will issue your Conformité Européenne Certificate. You will the need to draw up the EU Declaration of Conformity (per Article 19 and Annex IV of EU MDR).
The device needs to be registered in EUDAMED, using your SRN from actor registration. After this the CE mark may be affixed (under Article 20 of EU MDR), along with the Notified Body’s identification number, where it was involved.
Why Work With Us
We support you through:
- Device classification under MDR Annex VIII (Class I, IIa, IIb, III)
- Selecting the correct conformity assessment route and Notified Body
- Identification of Authorised Representative
- Preparing and compiling the technical documentation aligned with MDR Annex II and III requirements
- Development and maintenance of Clinical Evaluation Plans (CEPs) and Reports (CERs)
- Assessment of clinical data sufficiency and identification of evidence gaps
- Equivalence assessments where applicable
- Designing and executing systematic literature search protocols
- Alignment of clinical evaluation with MEDDEV 2.7/1 Rev. 4 methodology, MDCG 2020-5, 2020-6 and 2020-13, and EU MDR requirements
- Development of templates for post market surveillance documentation.
- Planning of PMS activities aligned with MDR Annex III requirements Liaising with Notified Bodies and responding to assessment queries
- Post-certification support for maintaining and renewing your CE certificate