RNCS Free Assessment
Service 2

Medical Device Single Audit Program (MDSAP)

Manufacturers often assume that MDSAP would simply mean one audit instead of several and then have been caught off guard by how much more thorough that one audit turns out to be. That gap between expectation and reality is worth closing before you commit resources to the program, which is the aim of this page: not just to define MDSAP, but to explain what it actually asks of your quality system.

Get Your Free Regulatory AssessmentAdditional topics on MDSAPLast reviewed: October 2026

What is MDSAP?

The Medical Device Single Audit Program (MDSAP) allows a single regulatory audit of a medical device manufacturer's quality management system to satisfy the requirements of multiple regulatory authorities. Instead of undergoing separate audits for each market, manufacturers can undergo one audit that meets the needs of several countries at once. While MDSAP participation can streamline compliance across markets, it also demands thorough, audit-ready documentation across all program areas (for more details MDSAP Audit Approach).

The program was developed by the International Medical Device Regulators Forum (IMDRF) to promote global regulatory convergence and to make oversight of device manufacturers more efficient and consistent.

It is worth being precise about what the trade-off actually looks like in practice: MDSAP audits run longer and dig deeper than a typical single-country inspection, because the auditor is verifying compliance against ISO 13485 plus the specific regulatory add-ons of every country in your certification scope, in one visit. Manufacturers who go in expecting a lighter version of a normal audit are usually the ones who find the preparation heavier than they budgeted for.

The program grew out of work by international regulators in the early 2010s who kept running into the same problem: the same manufacturer, the same quality system, audited separately and repeatedly by different countries. A three-year pilot beginning in 2014 tested whether a single, jointly recognized audit could hold up, and the results were strong enough that the participating authorities kept the program running permanently. It is now overseen by the MDSAP Regulatory Authority Council, made up of the five member regulators, which sets the audit requirements and authorizes the organizations permitted to conduct MDSAP audits.

Participating Regulatory Authorities

MDSAP is recognized by regulators in five jurisdictions:

  • United States: Food and Drug Administration (FDA)
  • Canada: Health Canada
  • Brazil: Agência Nacional de Vigilância Sanitária (ANVISA)
  • Australia: Therapeutic Goods Administration (TGA)
  • Japan: Ministry of Health, Labour and Welfare (MHLW) and the Pharmaceuticals and Medical Devices Agency (PMDA)

How Does It Work?

Audits are carried out by Auditing Organizations (AOs) that have been assessed and authorized under the program. These organizations audit the manufacturer against a common set of requirements, which include:

  • ISO 13485 (quality management systems for medical devices)
  • The specific regulatory requirements of each participating jurisdiction the manufacturer chooses to sell in

The audit follows a defined model that assesses processes such as management, device marketing authorization and facility registration, measurement, analysis and improvement, medical device adverse events and advisory notices reporting, design and development, production and service controls, and purchasing.

What sets an MDSAP audit apart from a standard ISO 13485 certification audit is that this sequence is fixed – it is not arbitrary.The MDSAP Audit Approach was developed to ensure AOs performed QMS audits in a consistent way. It defines the audit sequence, instructions for auditing each specific process, and identifies the linkages between processes. The audit approach is based on a foundation of risk management principles. The audit sequence follows four primary processes:

  • Management process
  • Measurement, Analysis and Improvement process
  • Design and Development process
  • Production and Service Controls process.

These primary processes all have linkages to the supporting Purchasing process, including supplier control and verification of purchased product.

There are two additional supporting processes that are necessary to meet specific jurisdictional regulatory requirements:

  • Device Marketing Authorization and Facility Registration
  • Medical Device Adverse Events and Advisory Notice Reporting.

Each process includes several tasks to be audited. While the sequence of processes to be audited is prescribed, auditors may audit tasks within a given process in any sequence to allow for an efficient and effective audit. The tasks required to be audited vary depending on if the audit is an initial certification, surveillance, re-certification, or special audit. Audits may be conducted offsite in a documentation review format, onsite, or in a remote capacity or a combination of these, depending on the type and nature of the audit.

After the audit has been conducted, the AO issues any nonconformities using a standard template and a final report to the medical device manufacturer. If nonconformities were raised, the manufacturer can formally respond and address these.

Nonconformities get graded by severity, and you are expected to respond with a real root-cause investigation and a corrective action plan within a set window. Not just a fix, but evidence that you understand why the gap happened in the first place. Once everything is closed out, the AO issues a standardized MDSAP Audit Report that every participating regulator can read and act on, which is really the mechanical heart of why one audit can stand in for several.

After the successful closure of an initial or re-certification audit, the AO will issue an MDSAP certificate. This certificate is an attestation by the AO that the facilities listed in the certificate have been audited against the listed criteria for the listed scope and found to conform to those requirements, including the regulatory requirements for the specific MDSAP Regulatory Authorities (RAs). Certificates are not normally issued after surveillance audits.

Getting Ready for an MDSAP Audit

  • There is no shortcut around the preparation, but there is a sensible order to it.
  • Start with an honest gap assessment against ISO 13485 and specific add-on requirements of each country you are planning to include, not a generic checklist exercise, but a real look at whether your procedures reflect what actually happens on your floor.
  • From there, clean up documentation and records so they hold up under the level of sampling an AO will apply, and run an internal audit structured around the same process sequence the AO will use. This will ensure that the first time your team experiences that sequence is not during the real thing. Only once those internal findings are genuinely closed, not just logged, does it make sense to lock in your AO and schedule the audit.

Where MDSAP Preparation Tends to Go Wrong

A few patterns show up often enough to be worth naming directly. Manufacturers coming from a single-market background frequently underestimate how much longer and deeper an MDSAP audit runs compared to what they are used to and build a preparation timeline that is too tight. Jurisdiction-specific requirements, the country specific add-ons layered on top of ISO 13485, are easy to miss if your existing QMS was built with only one regulator in mind. And because MDSAP includes annual surveillance audits, quality records and CAPA tracking need to stay genuinely current year-round, not just tidied up in the weeks before a scheduled visit.

Benefits for Manufacturers

  • Fewer audits: One audit can replace multiple country-specific inspections, saving time and resources.
  • Consistency: A standardized audit approach reduces variation in how requirements are assessed.
  • Faster market access: Streamlined compliance can support entry into several markets.
  • Stronger quality systems: The audit model encourages a thorough, process-based approach to quality and patient safety.

MDSAP and the FDA

Since FDA’s Quality Management System Regulation (QMSR) took effect on February 2, 2026, incorporating ISO 13485:2016 by reference, MDSAP audits now align more closely with what FDA inspectors look for. However, an MDSAP audit and an FDA inspection remain distinct: FDA inspections do not follow the MDSAP audit sequence, and a clean MDSAP certificate is a strong indicator, not a guarantee, of passing an FDA inspection.

The FDA may continue to accept MDSAP audit reports as a substitute for routine Agency inspections. This means eligible manufacturers participating in MDSAP may not be subject to routine FDA inspections, though the FDA retains the authority to conduct "for-cause" and certain other inspections when needed. Firms with activities related to the Electronic Product Radiation Control (EPRC) provisions of the Federal Food, Drug, and Cosmetic Act will continue to be subject to FDA inspections for the EPRC activities.

Read more about MDSAP and FDA's QMSR: How the Two Now Fit Together →

MDSAP Certification vs. ISO 13485 Certification

These two get confused often enough that it is worth being direct about the difference. An ISO 13485 certificate, issued by an accredited certification body, confirms your quality system meets the international standard. An MDSAP certificate, issued by a recognized Auditing Organization rather than a standard certification body, confirms that same ISO 13485 baseline plus the specific regulatory requirements of up to five national regulators, verified in a single audit. One tells you your QMS clears a global bar while the other tells you it clears that bar and the specific hurdles of every market in your certification scope.

Why Work With Us

  • Deep Regulatory Expertise – Beyond ISO 13485, we cover US, Canada, Brazil, Australia, and Japan requirements.
  • Tailored Approach – Gap analysis and plans aligned to your products, markets, and timelines.
  • End-to-End Support – From gap assessments and QMS remediation to mock audits, CAPA support, training, and ongoing compliance.
  • Audit-Ready Systems – Sustainable processes that stand up year after year, not just audit week.
  • Faster Market Access – Reduce duplicate inspections and streamline entry into multiple jurisdictions.
  • Clear Communication – Responsive team, plain-language guidance, and accountability throughout.

We can help ensure your documentation stands up to scrutiny, reducing the risk of findings that could delay certification or market access.

Ready to Get Started?

Whether you are preparing for your first MDSAP audit or strengthening an existing quality system, we are here to help. We would rather have a straight conversation about whether MDSAP makes sense for your specific markets and timeline than have you find out the hard way that the audit was bigger than expected. Send us your current market list and device classification and we will tell you plainly whether we think MDSAP is worth pursuing, before you spend anything on preparation. Contact us today to schedule a consultation.

Get Your Free Regulatory Assessment
Did you know?
  • Health Canada requires MDSAP certification for manufacturers selling Class II, III, and IV medical devices in Canada, making participation mandatory rather than optional for those companies.
  • Every MDSAP audit is required to start and end with the same process — Management — regardless of company size or device type, because leadership oversight is treated as the thread connecting every other area the auditor reviews.
MDSAP – Frequently Asked Questions
Is MDSAP mandatory?

It depends on the market. Health Canada requires MDSAP certification for manufacturers of Class II, III, and IV devices. In the US, Brazil, Australia, and Japan, participation is voluntary, though it can offer benefits such as reduced duplicate audits.

How is MDSAP different from ISO 13485 certification?

ISO 13485 certification confirms your QMS meets the international standard. MDSAP builds on ISO 13485 by adding the regulatory requirements of the participating countries, so one audit can serve several regulators.

Can MDSAP certificate be validated?

Yes, MDSAP certificates are used by many regulators globally and can be validated through the official website. Validate MDSAP Certificates | Medical Device Single Audit Program (MDSAP)

Can we change which countries are covered later?

Yes. Your MDSAP scope is not locked in permanently. Countries can be added or dropped in a future audit cycle as your markets change.

Does the certificate expire?

Yes. It runs on the same three-year cycle with annual surveillance audits, then a full recertification audit at the end of year three.

View All FAQs →
Contact us today

Tell us about your device and target market. Our regulatory specialist, not a salesperson, will reply within one business day.

Get Your Free Regulatory Assessment