ISO 13485 contains areas where an organization can define processes for itself, but several processes stand out as getting particular attention from auditors and inspectors. Ensuring the proper implementation of these processes realizes the maximum benefit of a QMS.

Document and Record Control

  • Organizations must establish and maintain procedures for the control of documents and records, including the quality manual, work instructions, and records generated by them, such as inspection records and training records.
  • Document and record control procedures should address the creation, review, approval, distribution, and revision of documents, and the preparation, identification, storage, retrieval, and disposal of records.
  • Procedures for document control are frequently cited during audits due to the ease with which out-of-date or missing documents can be observed by an auditor.

Design and Development Controls

  • ISO 13485 requires a controlled design and development process for medical devices that addresses the transition from design inputs (user needs / regulatory requirements / intended use) to design outputs, design verification and validation, and finally to design transfer into commercial production.
  • In addition, changes to device design must be documented and assessed for potential impact on device performance, as well as previously completed design verification and validation activities.
  • Design control procedures are one of the first areas that are typically reviewed by an auditor, especially for higher-risk devices, since they represent the traceability from need to device.

Risk Management (ISO 14971)

  • ISO 13485 requires documentation of a process for risk management, which is detailed in the companion standard ISO 14971. This includes identifying hazards, estimating and evaluating risk, implementing controls, and verifying that residual risk is acceptable.
  • Risk management should be integrated throughout the life cycle of a device, including input to design reviews, supplier management, CAPA, and the utilization of information received about the device once it is on the market.

Purchasing and Supplier Management

  • ISO 13485 places responsibility on manufacturers for the quality of purchased products and processes, even when performed by an outside supplier. This includes the evaluation and selection of suppliers based on specific criteria, the provision of necessary purchasing information to the supplier, and the verification that the delivered product or service meets purchase requirements.
  • The controls implemented for a supplier should be dictated by the risk that the purchased item or service presents to the final device.

Internal Audits and Management Review

  • Internal audits provide an organization with an opportunity to assess the effectiveness of its own processes, ideally in advance of an external auditor or inspector. Internal audit results are commonly used as inputs to management review, which is a formal, periodic assessment of the quality management system by organization management.
  • ISO 13485 emphasizes the importance of management review as a business process that evaluates the suitability, adequacy, and effectiveness of the QMS based on inputs such as internal audit results, complaint trends, and CAPA reviews.

CAPA (Corrective and Preventive Action)

  • CAPA processes represent the ability of an organization to learn from problems and implement changes to prevent them from recurring, including trending of nonconformities, investigations of the cause and contributing factors, and corrective and preventive action.
  • CAPA is consistently one of the most heavily scrutinized processes during third-party audits and FDA inspections since it reflects an organization's ability to learn and improve.

Complaint Handling and Post-market Surveillance

  • Complaints received from customers, distributors, and clinicians about a medical device following delivery represent one of the richest sources of information available to an organization.
  • A formal complaint handling procedure that includes investigation and evaluation of complaints, along with a process to determine if a complaint investigation requires regulatory notification (such as a Medical Device Report to the FDA), ensures that this critical source of quality information is captured and appropriately acted upon.
  • Under the EU MDR, post-market surveillance becomes even more explicitly required, representing one area in which CE-marked devices need to go beyond ISO 13485 requirements.

Training and Competence

  • Personnel performing work affecting the quality of a medical device must be trained to the level of education, training, skills, and experience necessary to perform their assigned tasks.
  • The organization must maintain training records that demonstrate that employees have received the training required, including any updates or modifications to documents and procedures affecting their work, to ensure awareness of the most current requirements.