RNCS Free Assessment
Quality Management System · 1.1

ISO 13485:2016 – Understanding the Structure

Next: Core processes in QMS →

ISO 13485 is divided into eight clauses, of which the first three specify the scope and give general information about the standard. The other five clauses concern the requirements for a quality management system that an organization must implement to obtain the ISO 13485 standard certification.

Clause 1: Scope

This clause specifies the standard’s applicability. ISO 13485 is intended for organizations that participate in the direct or indirect development of medical devices, including their manufacture, storage, distribution, installation, and servicing. In addition, it concerns all suppliers and external organizations providing services to the organization. Such applicability refers to any organization regardless of its size or the character of medical devices.

Clause 2: Normative references

This clause lists the standards which are referred to for the requirements, specifications, definitions, methods of tests, and other supporting information necessary for the use of the ISO 13485 standard. In this case, ISO 13485-1:2016 relies on the ISO 9000 standard, defining the terms common for quality management systems.

Clause 3: Terms and definitions

This clause specifies the terms and definitions related to medical devices, including a medical device, risk, labelling, implantable device, and sterile barrier system, among others. These terms must be used by an organization to properly understand and apply the requirements of the standard.

Clause 4: Quality management system

This clause establishes the general requirements for the quality management system. It concerns the establishment, implementation, and maintenance of the quality management system, including control of external processes and external suppliers. Moreover, the requirements for documentation of the quality management system, such as the quality manual, medical device file, document control, and records control, are presented.

Clause 5: Management responsibility

The main aim of this clause is to establish the requirements for management responsibility in terms of a quality management system. It states that top management shall show commitment and shall be responsible for the quality management system. For example, they should establish the quality policy and set relevant quality objectives and ensure their achievement. Top management shall also consider customer and regulatory requirements, determine the organization’s needs, provide resources, define authorities, and perform regular management reviews.

Clause 6: Resource management

This clause indicates the requirements for resources that should be controlled by the organization to ensure effective quality management system implementation. In particular, they concern competent personnel who possess the necessary skills, knowledge, and experience. Moreover, the requirements relate to infrastructure, including buildings, equipment, and a controlled environment, such as the prevention of contamination.

Clause 7: Product realization

This clause stipulates the requirements for the realization process of the product, which is the most detailed one among all clauses. It covers product realization planning, customer-related processes, design and development, purchasing and control of suppliers, and production and service provision. Moreover, it addresses the control of monitoring and measuring equipment, including its calibration.

Clause 8: Measurement, analysis and improvement

The requirements of the last clause of the ISO 13485 standard relate to the feedback function of a quality management system. They stipulate the need for implementing a closed-loop process for complaints handling, feedback collection, analysis of data, audits, and inspections, including the control of nonconformities. Moreover, the requirements concern continual improvement and management of product realization through various activities, such as corrective and preventive actions, CAPA (Corrective and Preventive Actions), recall, and notification.

Contact us today to strengthen your compliance framework and secure confidence in both regulators and patients.

Last reviewed: October 2026

Contact us today

Tell us about your device and target market. Our regulatory specialist, not a salesperson, will reply within one business day.

Get Your Free Regulatory Assessment