RNCS Free Assessment
Quality Management System · 1.3

ISO 13485 Certification Process

Next: eQMS (Electronic Quality Management System) →
ISO 13485 Certification Process
  1. Step 1Gap Analysis

    Compare current processes against ISO 13485 requirements to identify documentation and control gaps. Involve ISO 13485 consultants, if needed.

  2. Step 2QMS Design & Documentation

    Develop the Quality Manual, SOPs, and records including document control, risk management, CAPA, and supplier controls.

  3. Step 3Implementation & Training

    Roll out QMS procedures across the organization and train employees to embed quality practices.

  4. Step 4Internal Audit

    Verify QMS effectiveness and identify non‑conformances before external assessment.

  5. Step 5Management Review

    Senior leadership reviews QMS performance, audit results, and improvement opportunities.

  6. Step 6Certification Audit

    Undergo certification audit

  7. Step 7Certification Decision & Issuance

    Certification body issues ISO 13485 certificate valid for 3 years, subject to surveillance audits.

  8. Step 8Maintain compliance

    Complete annual surveillance audits and recertification at the end of the 3‑year cycle.

Certified & maintained

Step 1: Gap Analysis

Before anything else, your team needs to understand the current state of your operations and how they compare to the requirements set by ISO 13485. The gap analysis will involve:

  • Reviewing and analyzing your quality process and procedures to identify what is already covered and what is missing (e.g., risk management processes, design controls, etc.)
  • Evaluating the overall quality management maturity, even for those processes that may not be formally documented
  • Reporting and prioritizing the analysis results based on severity and required effort for implementation

This first step sets the foundation for your entire project, so it is important to invest enough time and effort to develop a comprehensive report.

Step 2: QMS Design & Documentation Development

Using the information discovered in your gap analysis, you will be designing and developing QMS documents that will be used in your day-to-day operations to meet the requirements of ISO 13485. These typically include:

  • The quality manual that describes the scope of your QMS
  • Standard Operating Procedures and Work Instructions that relate to procedures for document control, design and development, purchasing, production, CAPA, audits, management reviews, and more
  • Records and forms that will collect and store information generated by your QMS processes

While developing documents, ensure you focus on your specific needs based on the processes covered by your QMS and not generic requirements. The auditor will look for evidence that your documented procedures reflect your actual practices. Therefore, it is better to be precise when developing your documents.

Step 3: Implementation & Organization-Wide Rollout

Having quality documents is a good start, but they will not ensure your success unless you implement the described processes across your organization and train your employees at every level to understand their role within the QMS. This step normally takes the longest since it requires:

  • Communicating new or revised processes to relevant departments
  • Assigning process owners and responsibilities based on roles and responsibilities
  • Updating procedures, workflows, forms, and templates, if needed
  • Living the QMS to generate real records and evidence of implementation
  • Role-specific training for employees on relevant SOPs and work instructions
  • General QMS awareness training to all employees (quality policy, objectives, regulatory context)
  • Specialized training for device design and development, risk management, and CAPA teams
  • Maintaining training records of employees

Depending on the complexity of your processes and the size of your team, this stage can take anywhere from a few weeks to several months. Well-documented training records (under ISO 13485 clause 6.2) demonstrate that the organization takes competency seriously, which auditors view as a strong indicator of QMS maturity.

Step 4: Internal Audit

Before you invite a third-party certification body to review your processes, you need to make sure that everything is compliant with the requirements of ISO 13485. This will involve designing an internal audit program that will cover all relevant sections and processes and assigning the necessary resources. This will involve:

  • Planning an internal audit schedule
  • Conducting audits using trained internal auditors (or outsourced specialists like RNCS)
  • Documenting findings of the audit, including nonconformances and observations
  • Raising CAPAs for any identified gaps and tracking them to closure

Internal audits serve as a "dress rehearsal," and help catch issues that may be easily rectified, before they become findings in the certification audit.

Step 5: Management Review

Top management must formally review the QMS's performance before starting the certification process. A management review typically covers:

  • Quality policy and objectives
  • Results of internal and external audits
  • Customer feedback and complaint trends
  • Status of CAPAs and their effectiveness
  • Process performance and product conformity data
  • Changes that could affect the QMS (regulatory, organizational, or market-driven)
  • Recommendations for improvement
  • Resource adequacy

This review is a mandatory requirement under ISO 13485 clause 5 and must be documented. The management review demonstrates that the top management is actively involved in improving the quality of the organization.

Step 6: Certification Audit

Your team will need to select an appropriate certification body to perform a certification audit. If you are targeting countries that have adopted the MDSAP, you may want to consider selecting a certification body that is recognized under the Medical Device Single Audit Program. Factors to consider include:

  • Accreditation scope and recognition in target markets
  • Industry experience and auditor expertise in medical devices
  • Cost and audit scheduling flexibility

There are two stages for a certification audit

  • Documentation review (to determine readiness for the certification audit)

The certification body will conduct an initial documentation review to ensure that your procedures are aligned with the requirements of ISO 13485, and you are ready for a full on-site certification audit. The documentation review can be performed onsite or remotely and normally takes a few days to a week.

The certification body will identify any major documentation findings or deficiencies that may require attention of your team before proceeding to the next stage.

  • On-site assessment

The certification body will perform a full on-site certification audit to evaluate your procedures and processes. Auditors would typically:

  • Interview staff across various departments to verify process understanding.
  • Review actual records, such as CAPAs, design files, training logs, supplier evaluations, complaint handling, etc., not just procedures.
  • Observe production, storage, or service areas, where applicable.
  • Identify nonconformances (major and minor), if any, and provide observations for improvement.

Addressing Findings & Closing Nonconformances

If nonconformances are identified during the audit, you must:

  • Conduct root cause analysis
  • Implement corrective actions
  • Provide objective evidence of resolution to the certification body within a defined timeframe

Step 7: Certification Decision & Issuance

Once all findings are resolved, the certification body issues the ISO 13485 certificate which is typically valid for three years. This certificate confirms that your organization's QMS meets ISO 13485 requirements and can be used to support regulatory submissions and market access globally.

Step 8: Maintain Compliance

Surveillance Audits

ISO 13485 Certification is not a one-time event. To maintain the certification, you need to undergo periodic surveillance audits, typically annually, which:

  • Sample specific clauses or processes rather than auditing the entire QMS each time
  • Verify continued compliance and effectiveness
  • Check that previous findings remain closed and that the QMS continues to evolve appropriately

Recertification Audit

At the end of the three-year certification cycle, a full recertification audit is conducted to renew the certificate for another three-year term. This is similar in depth to the original Stage 2 audit.

Contact us to explore how we can help you establish a quality system.

Last reviewed: October 2026

Contact us today

Tell us about your device and target market. Our regulatory specialist, not a salesperson, will reply within one business day.

Get Your Free Regulatory Assessment